  data sheet these platinum resistance bulbs are convenient for mea - suring a wide range of temperatures in plants and the like. the resistance element is protected by an internal tube and moreover by an external tube in order to fully with - stand high temperature, high pressure and corrosion. a contact strip is inserted between the internal and external protecting tubes, which enables a quick response and ensures high resistance to vibration. applicable standard: jis c 16041997 resistance element: kind of element and nominal resistance value; pt100 w class; b class, a class prescribed current; 2ma temperature accuracy; class accuracy a (0.15 + 0.002t) c b (0.3 + 0.005t) c note: (1) t is measuring temperature indi - cated in c and unrelated to the + and C signs. (2) accuracy means maximum allow - able limit when subtracting the re-sistance value of resistance element from the temperature in terms of resistance calculated ac - cording to the standard resistance table. protecting tube material: s ; 304 stainless steel w ; 316 stainless steel *t ; 316l stainless steel mounting method and shape of protecting tube: mounting method: insertion type; either movable flange (ftr), mov - able airtight fange (ftt), or movable airtight screw (fts) is employed for mounting screw-in type; g3/4 (pt3/4) or r3/4 (pt3/4) external thread (impossible with h type) flange type; jis 10k-25a ? jis 20k-25a jis 30k-25a or jis 63k-25a (impossible with n or p type) insertion length: see page 3 structure of element: 1; single element 2-wire method (100 w b class) 3; single element 3-wire method (100 w b class) 4; double element 2-wire method (100 w b class) 6; double element 3-wire method (100 w b class) 7; single element 3-wire method (100 w a class) 8; double element 3-wire method (100 w a class) platinum resistance bulb for general use ftf specifications a insertion type mounting method screw-in type f j m protecting tube shape screw-in type flange type b g l n c h ? p date EDS2-21C jan. 31, 2007
ftf  a b c f g h j l m n p note: manufacturing possible manufacturing possible flameproof-explosionproof-possi - ble working conditions: see page 4 terminal box: material; diecast aluminum alloy conduit connection; g1/2 (pf1/2) (jis 15c) two conduit connections should be provided with double element 3-wire re-sistance bulb. coating; baked melamine resin finish color; silver nominal resistance table: see page 3 scope of delivery: platinum resistance bulb 1, 3 7 4 6, 8 (a) when the element code no. 6 is used, the terminal box form should be provided with two conduit connections. (b) feasible combinations of element and mounting method. manufacturing possible explosionproof structure possible note: *(1) combination of protecting tube shape and mounting dimension feasible combinations of mounting method and ele - ment structure: *(2) cabtyre cable of 1m lg. is provided when the flling com - pound is used. code symbols 4 f t f - 10 2 1 3 4 5 6 7 8 11 12 13 9 description a b c f g h j l m n p a b c f 0 1 2 3 4 5 6 7 8 015 295 1 2 3 4 7 8 0 s w t 1 3 4 6 7 8 asterisked ( * ) items : non-standard * * * * (1) * (2) * * * * * mounting method insertion type insertion type insertion type screw-in type (for low temperature) screw-in type (for low temperature) screw-in type (for low temperature) screw-in type (for high temperature) screw-in type (for high temperature) flange type flange type flange type protecting tube material 304 stainless steel 316 stainless steel 316l stainless steel mounting dimension flange jis 10k-25a flange jis 20k-25a flange jis 30k-25a flange jis 63k-25a (impossible with mounting method n or p) mounting thread g3/4 (pf3/4) mounting thread r3/4 (pt3/4) (combination with h type mounting method is excluded) insertion type insertion length [mm] fill in insertion length in cm unit (according to table of insertion lengths) ex.:insertion length 500mm 050 structure/explosionproofing standard type plastic terminal type flameproof type (d2g4) system intrinsically safe explosion- proofing (i3ng5) for connection with zener barrier lining and filling compound lining none none none lead homogen lead homogen lead homogen kel-f kel-f kel-f filling compound none paraffin silicon grease none paraffin silicon grease none paraffin silicon grease element single element 2-wire method (100 ? b class) single element 3-wire method (100 ? b class) double element (double winding) 2-wire method (100 ? b class) double element (double winding) 3-wire method (100 ? b class) single element 3-wire method (100 ? a class) double element 3-wire method (100 ? a class) note:100 ? , 0.5 class is standard. 1000mm 100 a insertion type mounting method screw-in type f j m protecting tube shape screw-in type flange type b g l n c h ? p a b c f g h j l m n p 1, 3 7 4 6, 8
 a 150 200 250 300 350 400 450 500 550 600 650 700 750 800 850 900 950 1,050 1,150 1,250 1,350 1,450 insertion length (unit: mm) [dimension "l" of "outline diagram"] mounting method b 150 200 250 300 350 400 450 500 550 600 650 700 750 800 850 900 950 1,050 1,150 1,250 1,350 1,450 f 150 200 250 300 350 400 450 500 550 600 650 700 750 800 850 900 1,000 1,100 1,200 1,300 1,400 g 150 200 250 300 350 400 450 500 550 600 650 700 750 800 850 900 1,000 1,100 1,200 1,300 1,400 c 200 250 300 350 400 450 500 550 600 650 700 750 800 850 900 950 1,050 1,150 1,250 1,350 1,450 1,550 1,650 1,750 1,850 1,950 2,450 2,950 h 200 250 300 350 400 450 500 550 600 650 700 750 800 850 900 1,000 1,100 1,200 1,300 1,400 1,500 1,600 1,700 1,800 1,900 2,400 2,900 j 150 200 250 300 350 400 450 500 550 600 650 700 750 800 900 1,000 1,100 1,200 1,300 l 150 200 250 300 350 400 450 500 550 600 650 700 750 800 900 1,000 1,100 1,200 1,300 m 150 200 250 300 350 400 450 500 550 600 650 700 750 800 850 950 1,050 1,150 1,250 1,350 n 150 200 250 300 350 400 450 500 550 600 650 700 750 800 850 950 1,050 1,150 1,250 1,350 p 200 250 300 350 400 450 500 550 600 650 700 750 800 850 950 1,050 1,150 1,250 1,350 1,450 1,550 1,650 1,750 1,850 2,350 2,850 insertion length insertion length nominal resistance value of resistance bulb jis c 1604-1997 remarks: the resistance values given in the above table are those when nominal resistance value "r 0 " is 100 w . (unit: w ) temp. [c] temp. [c] temp. [c] ?100 0 0 100 200 300 400 500 600 ?0 60.26 100.00 0 100.00 138.51 175.86 212.05 247.09 280.98 313.71 0 ?10 56.19 96.09 10 103.90 142.29 179.53 215.61 250.53 284.30 316.92 10 ?20 52.11 92.16 20 107.79 146.07 183.19 219.15 253.96 287.62 320.12 20 ?30 48.00 88.22 30 111.67 149.83 186.84 222.68 257.38 290.92 323.30 30 ?40 43.88 84.27 40 115.54 153.58 190.47 226.21 260.78 294.21 326.48 40 ?50 39.72 80.31 50 119.40 157.33 194.10 229.72 264.18 297.49 329.64 50 ?60 35.54 76.33 60 123.24 161.05 197.71 233.21 267.56 300.75 60 ?70 31.34 72.33 70 127.08 164.77 201.31 236.70 270.93 304.01 70 ?80 27.10 68.33 80 130.90 168.48 204.90 240.18 274.29 307.25 80 ?90 22.83 64.30 90 134.71 172.17 208.48 243.64 277.64 310.49 90 ?100 18.52 60.26 100 138.51 175.86 212.05 247.09 280.98 313.71 100
ftf  s w t application used for corrosive gas or liquid, and when the insertion length is desired to be adjustable mass{weight} 0.5 to 2 kg outline diagrams fig. 1 fig. 2 model 1 3 4 6 7 8 a ftf working temperature, working pressure ditto used when especially short time lag is required 0.5 to 1.5 kg fig. 3 working conditions ftf 1 3 7 s w t b ftf 1 3 7 s w t c 1 3 4 6 7 8 s w t ftf f j 1 3 7 ftf s w t g l 1 3 7 ftf s w t h 1 3 4 6 7 8 s w t h ftf ftf 1 3 7 s w t n ftf 1 3 7 s w t p working temp.; C200 to +650 c working pressure; atmospheric pressure when both movable airtight screw and fange are used, working pressure can be up to 0.1mpa {1.02kgf/cm 2 } ditto working temp.; C200 to +650 c working pressure; less than fange (jis) nominal pressure jis 10k-25 ? jis 20k-25 jis 30k-25 ? jis 63k-25 material; 304, 316, 316l stainless steel working temp.; C200 to +650 c working pressure; less than fange (jis) nominal pressure jis 10k-25 ? jis 20k-25 jis 30k-25 material; 304, 316, 316l stainless steel ditto ditto ditto used when greater insertion length is required used for corrosive gas or liquid. used for comparatively high temp., high pressure. j type is used when the temp. in the terminal box is expected to rise or when there is heat- retaining material used for corrosive gas or liquid. l type is used when the temp. in the terminal box is expected to rise or when there is heat- retaining material, or used when especially short time lag is required used for water, air, corrosive gas etc., and especially in case greater insertion length is re - quired used for corrosive gas or liquid etc., and especially in case air- tightness is required ditto used when especially short time lag is required ditto used when especially long insertion length is required note: when the resistance bulb is used at a place of low temperature (below 0 c) or of high temperature, use a bulb which is flled inter - nally with paraffn or silicon compound after connecting the cable. paraffn can be used in a range of 0 to 50 c and silicon in a range of C 60 to + 150 c. 0.7 to 4.4 kg fig. 4 0.5 to 1.8 kg fig. 5 fig. 6 fig. 7 fig. 8 0.5 to 1.5 kg fig. 9 fig. 10 1.2 to 6.3 kg fig. 22 fig. 23 fig. 24 1.4 to 3.8 kg fig. 12 fig. 13 fig. 14 fig. 15 fig. 16 fig. 17 fig. 18 1.4 to 3.8 kg fig. 19 fig. 20 fig. 21 1 to 3 kg fig. 11 ( ) 100 500 c -200 0 4 mpa 5 100 500 c -200 0 3 mpa 3.5 100 500 c -200 0 mp a 2 1.5
 (refer to working conditions of page 4) determine insertion length "l" by collating the 5th digit of code symbols with the table shown on page 3. for example, when the 5th digit of code symbol is a, se - lect "l" from 22 lengths, 150mm to 1450mm, by the table shown on page 3. insertion type screw-in type dimension "a" on the neck part of screw-in type is as fol - lows. 5th digit of code symbols f, g j, l a 50mm 150mm fig. 1 ftf a f s w t 04 - ??? a 1 3 4 7 fig. 2 ftf a f s w t 04 - ??? a 6 8 fig. 3 ftf a f s w t 04 - ??? b 1 3 7 fig. 4 ftf a f s w t 04 - ??? c 1 3 7 fig. 5 ftf 1 3 4 7 a f s w t 74 - ??? f j fig. 6 ftf 1 3 4 7 a f s w t 84 - ??? f j fig. 7 ftf a f s w t 74 - ??? f j 6 8 fig. 8 ftf a f s w t 84 - ??? f j 6 8 outline diagram [unit:mm]
ftf  flange type ftf a f s w t 74 - ??? g l fig. 9 1 3 7 ftf a f s w t 84 - ??? g l fig. 10 1 3 7 fig. 11 ftf a f s w t 74 - ??? h 1 3 7 ftf a f s w t 14 - ??? m 1 3 4 7 fig. 12 ftf a f s w t 24 - ??? m 1 3 4 7 fig. 13 ftf a f s w t 34 - ??? m 1 3 4 7 fig. 14 ftf a f s w t 44 - ??? m 1 3 4 7 fig. 15
 ftf a f s w t 24 - ??? p 1 3 7 fig. 23 ftf a f s w t 14 - ??? p 1 3 7 fig. 22 ftf a f s w t 14 - ??? m 6 8 fig. 16 ftf a f s w t 24 - ??? m 6 8 fig. 17 ftf a f s w t 34 - ??? m 6 8 fig. 18 ftf a f s w t 14 - ??? n 1 3 7 fig. 19 ftf a f s w t 24 - ??? n 1 3 7 fig. 20 ftf a f s w t 34 - ??? n 1 3 7 fig. 21
ftf  terminal box for fameproof type movable airtight screw (type fts) 2, 4, 6 in 4th digit of code mass {weight} [kg] protecting tube outer dia. ( d) type d 1 approx. ? fts6e fts6d fts4c fts2a 31 28 24 13 r1 1/4 (pt1 1/4) r3/4 (pt3/4) d 2 r1 (pt1) r1 1/4 (pt1 1/4) a 58 58 50 38 b 30 30 20 20 100 100 80 80 30 25 to 27 21.3 to 22 12 1.2 1.2 0.8 0.8 1, 3, 5 in 4th digit of code note: material is ss400 mass {weight} [kg] type d 1 fts5e fts5d fts3c fts1a 31 28 24 13 g1 1/4 (pf1 1/4) g3/4 (pf3/4) d 2 g1 (pf1) g1 1/4 (pf1 1/4) a 69 69 59 48 b 58 58 50 38 30 25 to 27 21.3 to 22 12 1.2 1.2 0.8 0.8 note: material is ss400 100 100 80 80 c 30 30 20 20 protecting tube outer dia. ( d) fig. 24 ftf a f s w t 34 - ??? p 1 3 7 100 125 cap g1/2 (pf1/2) approx. ?
 movable airtight fange (type ftt) jis 10k-50 fange movable fange (type ftr) jis 10k-50 fange jis 5k-25 fange d 31 28 24 protecting tube outer dia. ( d) 30 26.8? 27 21.3 ? 21.7 ? 22 jis 10k-25 fange material ss400 ftt2d ftt2c ftt2a 28 24 13 26.8 ? 27 21.3 ? 21.7 ? 22 12 fc200 protecting tube outer dia. ( d) type d material ftt1d ftt1c ftt1a 28 24 13 26.8 ? 27 21.3 ? 21.7 ? 22 12 fc200 protecting tube outer dia. ( d) type d material 50 31 28 24 13 49 30 25 to 27 21.3 to 22 12 ss400 protecting tube outer dia. ( d) d material jis 10k-25 fange protecting tube outer dia. ( d) type d material ftr2d ftr2c ftr2a 28 24 13 25 to 27 21.3 to 22 12 fc200 jis 5k-25 fange protecting tube outer dia. ( d) type d material ftr1d ftr1c ftr1a 28 24 13 25 to 27 21.3 to 22 12 fc200
ftf information in this catalog is subject to change without notice. printed in japan head office gate city ohsaki, east t ower , 11-2, osaki 1-chome, shinagawa-ku, t okyo 141-0032, japan http://www .fesys.co.jp/eng instrumentation div . international sales dept. no.1, fuji-machi, hino-city , t okyo, 191-8502 japan phone: 81-42-585-6201, 6202 fax: 81-42-585-6187 http://www .fic-net.jp/eng caution on safety *before using this product, be sure to read its instruction manual in advance.


▲Up To Search▲   

 
Price & Availability of EDS2-21C

All Rights Reserved © IC-ON-LINE 2003 - 2022  

[Add Bookmark] [Contact Us] [Link exchange] [Privacy policy]
Mirror Sites :  [www.datasheet.hk]   [www.maxim4u.com]  [www.ic-on-line.cn] [www.ic-on-line.com] [www.ic-on-line.net] [www.alldatasheet.com.cn] [www.gdcy.com]  [www.gdcy.net]


 . . . . .
  We use cookies to deliver the best possible web experience and assist with our advertising efforts. By continuing to use this site, you consent to the use of cookies. For more information on cookies, please take a look at our Privacy Policy. X